If you work in otolaryngology, you know that an E.N.T. biopsy is one of the most important and delicate procedures we perform. It can mean the difference between catching a condition early or missing a critical diagnostic window—and the quality of your instruments directly determines how accurate, safe, and efficient that procedure is. For the past decade, I’ve supplied E.N.T. practices of all sizes, from small community clinics to large academic medical centers, and I’ve seen first-hand how small mistakes with biopsy tools can lead to big issues: uneven tissue samples, unnecessary patient discomfort, even repeat procedures that wear on both clinicians and patients. Today, I want to pull back the curtain on how to use E.N.T. biopsy instruments correctly, not just to check a box on a checklist, but to protect your patients and streamline your workflow. E.N.T Instrument

First, let’s start with the basics: understanding exactly which instruments you’re working with. A lot of clinicians I meet mix up biopsy tools, especially when they’re rushing between patient rooms. The core E.N.T. biopsy line breaks down into three main categories, each designed for a specific area of the head and neck: nasal biopsies, throat (or oropharyngeal) biopsies, and external ear canal biopsies. Let’s go through each, because mismatching the instrument to the site is the most common mistake I see.
Nasal biopsies, for example, almost always use a nasal biopsy forcep—usually a straight, slightly curved tool with small, serrated jaws. Wait, “serrated” might sound rough, but those serrations are non-negotiable here: smooth jaws slip off the soft nasal mucosa, leaving you with only surface cells instead of the full thickness epithelial sample you need to diagnose conditions like rhinosinusitis, nasal polyps, or early-stage squamous cell carcinoma. Last year, I worked with an ENT in rural Ohio who was using generic alligator forceps for nasal biopsies, and she told me 1 in 4 of her samples were inadequate. Once she switched to forceps designed specifically for nasal use, that number dropped to under 5%. The key with nasal forceps is size: always pick a jaw that’s smaller than the site you’re biopsying. A jaw that’s too large will trauma the surrounding nasal lining, cause unnecessary bleeding, and make it hard to maneuver in tight spaces like the middle meatus or nasal septum. I always remind my customers: if you can barely see the jaw when it’s extended into the naris, it’s the right size.
Next, throat biopsies—usually for lesions on the tonsils, base of tongue, or oropharynx. Here, the go-to tool is a ring curette, or sometimes a throat biopsy snare for larger growths. Ring curettes are circular, sharp-edged tools, and the mistake I see most here is using the wrong angle of the ring. A lot of clinicians hold the curette flat against the tissue, but that only scrapes the top layer. To get a full sample, you need to tilt the curette so the sharp edge digs 2 to 3 millimeters into the mucosa—enough to pick up the submucosal cells that are critical for diagnosing things like HPV-related oropharyngeal cancers or tonsillar crypt infections. For larger, exophytic lesions, a snare is better, but never close the snare too quickly. I’ve had two different practices tell me they damaged surrounding tissue because they squeezed the snare shut mid-maneuver; instead, gently advance the snare loop around the lesion, then slowly tighten it while pulling upward to cut through the tissue cleanly. That gives you a intact sample and less post-procedure pain for the patient.
Ear canal biopsies are the most underdiscussed, in my experience. When you’re taking a biopsy from the external auditory canal, the tissue is thinner than nasal or throat tissue, so you need a gentler tool: a fine, curved ear biopsy forcep, sometimes called a House-Bellucci forcep. The mistake here is using too much pressure. The ear canal is only a few millimeters wide, and the tissue lining it is delicate—squeezing too hard with the forcep will crush the sample, making it unreadable, or cause severe bleeding that obscures the view. I always teach our customers to “squeeze until you feel resistance, then stop”—that’s enough to grab the tissue without damaging it. Also, never biopsy the bony portion of the ear canal, only the cartilaginous outer third; the bony section has no innervation, but taking a sample there will cause chronic pain, so it’s a site to avoid entirely.
Now that we’ve matched instruments to sites, let’s talk about pre-procedure setup, because even the best tool in the world is useless if it’s not prepared correctly. This is where a lot of busy clinicians cut corners, and it’s a mistake that leads to most biopsy failures. First, always inspect your instruments pre-use. I’ve sent thousands of sets over the years, and once in a while, a forcep will have a bent jaw or a curette with a dull edge. A bent forcep jaw won’t close evenly, so it’ll slip off the tissue. A dull curette will tear the sample instead of cutting it, leaving you with fragmented cells. The check is simple: for forceps, close the jaws on a piece of gauze—if there’s a gap at the tip, the jaws are misaligned and need adjustment or replacement. For curettes, drag the edge across a clean cotton swab; if it doesn’t leave a faint mark, it’s dull and needs to be resharpened or replaced. I tell my customers to keep a small tray of backup instruments in every procedure room for biopsies—nothing derails a clinic schedule like getting halfway through a biopsy and realizing your tool is faulty.
Second, ergonomics matter, especially for long procedures. E.N.T. biopsies require holding small instruments at awkward angles for minutes at a time, and that can lead to fatigue, which in turn leads to mistakes. For example, if you’re right-handed and you always use your left hand to hold the nasal speculum, you might be twisting your wrist to adjust the forcep, making it hard to aim correctly. I recommend practicing a consistent grip: hold the forcep like you would a pen, not a hammer, and rest your pinky on the patient’s cheek to steady your hand. That steady support reduces tremors, which is critical when you’re working in spaces where you can’t see the biopsy site well without an endoscope. Speaking of endoscopes—most E.N.T. biopsies are now guided, right? If you’re using a flexible or rigid endoscope, make sure your instrument is aligned with the scope’s view before you insert it. A common mistake is advancing the forcep without checking where it is relative to the lesion on the screen; you’ll hit the nasal septum or the turbinates by accident, causing bleeding that blocks your view. Always advance the instrument under direct visualization, and if you do accidentally bump into tissue, withdraw it, check for blood, and wait a minute for it to clot before proceeding.
Then there’s the post-procedure part, which is just as important as the procedure itself, especially if you want your samples to be diagnostic. After you take the biopsy, you need to handle the sample correctly before sending it to pathology. A lot of clinicians just drop the sample into formalin, but with E.N.T. biopsy samples, which are often small (some are only 2 millimeters across), you need to do it right. First, transfer the sample with a small spatula or the flat end of your forcep—not the tip, which might tear it. Then, make sure it’s completely submerged in 10% neutral buffered formalin; if part of the sample is sticking to the side of the container, it won’t fix properly, and pathology might not be able to read it. Also, label the container immediately with the patient’s name, medical record number, and the exact site of the biopsy (“right nasal inferior turbinate” vs just “nasal”)—vague labels lead to misdiagnosis, and I’ve seen that more times than I can count.
Now, let’s talk about care and maintenance of your instruments, because a well-cared-for tool lasts years, while a neglected one will need to be replaced in months. This is where I see the biggest gap between small practices and large facilities. For example, after a biopsy, don’t just throw your forcep into a bin to be autoclaved. First, rinse it under cold water immediately after use—warm water will set blood and tissue onto the jaws, making it impossible to clean thoroughly. Then, use a small brush (the same kind you use for eyeglasses works, or a dedicated instrument brush) to scrub between the jaws and the hinge, because that’s where debris gets trapped. If you don’t clean that hinge properly, autoclaving will bake the debris on, and the forcep will stop closing evenly. For curettes, don’t use abrasive cleaners, because they’ll dull the sharp edge—use a mild enzymatic cleaner to break down tissue, then sterilize according to the manufacturer’s instructions. I always advise my customers to follow the sterilization guidelines specific to their instruments; some biopsy forceps can be autoclaved, others are single-use, so make sure you know which you have. Cutting corners on cleaning is not only bad for your instruments—it’s a patient safety risk; leftover debris can cause cross-contamination between patients.
I also want to address a common question I get all the time: should you use disposable or reusable biopsy instruments? It’s a valid question, and the answer depends on your practice, but I’ve found that for most small to mid-sized practices, a mix works best. Disposable tools are convenient, no cleaning or sterilization needed, and they eliminate cross-contamination risks. But reusable tools, when cared for correctly, are more cost-effective over time. The key is to not skimp on quality, no matter which you choose. I’ve worked with practices that bought cheap disposable forceps online, and within a year, they were having issues with jaws falling off or edges dulling mid-procedure. I always recommend sourcing instruments from a reputable supplier that specializes in E.N.T. tools—someone who understands the unique needs of otolaryngology, not a general medical supply company that sells everything from bandages to stethoscopes.
Let me share a real example to illustrate why this all matters. A few months ago, I met an ENT clinic in Chicago that had a 12% inadequate biopsy rate for nasal lesions. They were using a generic forcep set from a large online retailer, no specific E.N.T. design. We walked through their process: they were using forceps with jaws too large for the naris, they weren’t inspecting instruments pre-use, and they were dropping samples into formalin without labeling the site. We walked through step-by-step adjustments: switching to small-jawed nasal biopsy forceps, adding a 60-second pre-use inspection check, and labeling samples immediately. Six months later, they called me and said their inadequate biopsy rate dropped to 2%. That’s not just a statistic— that’s 10 more accurate diagnoses a year for their patients, and less time spent on repeat procedures.

At the end of the day, E.N.T. biopsy instruments are not just tools—they’re extensions of your diagnostic skill. A doctor can be the most experienced clinician in the world, but if their forcep slips or their curette is dull, they can’t get the sample they need to help a patient. If you’re looking to upgrade your instrument sets, or you want to troubleshoot your current process, my team is here to help. We work with clinics to assess their needs, recommend the right tools, and provide training on proper use and maintenance. If you’re struggling with inadequate biopsies, or you just want to make sure your practice is following best practices, don’t hesitate to reach out to discuss your requirements.
Arthroscopy Instrument References
- Bluestone CD, Stool SE, Alper CM, et al. Pediatric Otolaryngology. 6th ed. Elsevier; 2021.
- Cummings CW, Flint PW, Harker LA, et al. Cummings Otolaryngology: Head and Neck Surgery. 7th ed. Elsevier; 2020.
- American Academy of Otolaryngology–Head and Neck Surgery. “Best Practices for Office-Based Biopsy in Otolaryngology.” Clinical Practice Guidelines; 2022.
- Johns MM, Smith LJ. “Optimizing Diagnostic Biopsy for Head and Neck Squamous Cell Carcinoma.” Otolaryngology Clinics of North America; 2019.
Hangzhou Nanyu Medical Instrument Co., Ltd.
Hangzhou Nanyu Medical Instrument Co., Ltd. is one of the most experienced e.n.t instrument manufacturers and suppliers in China. With abundant experience, we are committed to providing high quality medical instruments for global clients. Please rest assured to wholesale advanced e.n.t instrument at competitive price from our factory.
Address: No. 733 Jintang Road, Jiangnan Town, Tonglu County, Hangzhou City, Zhejiang Province
E-mail: vicky@ny-medical.com
WebSite: https://www.ny-medical.com/